The 50/11 MEGA door is uniquely designed to meet the demands of the commercial and freight sector. With enlarged dimensions that ensure efficient and safe handling of heavy loads, this model is essential for projects seeking maximum capacity and reliability.
This model stands out for its combination of robust construction and cutting-edge features, offering the perfect balance between functionality and aesthetics in commercial and heavy-dutty applications. These doors are ideal for larger buildings or those with high passenger traffic, where load capacity and durability are key factors.
| Door cycles per year: | Up to 800.000 | ||
| Traffic peak of the door: | Up to 240 cycles per hour | ||
| Traffic lift speed: | Up to 3 m/s |
| Opening | Clear opening – PL (mm) | Clear height – HL (mm) | |||
| Steel Panels | Glass Panels | Steel Panels | Glass Panels | ||
| Car | C2 – T2 – T3 | 600 – 1.400 | 600 – 1.400 | 2.000 – 3.000 | 2.000 – 3.000 |
| C4 | 600 – 3.000 | 600 – 3.000 | |||
| C6 | 1.450 – 3.000 | 1.450 – 3.000 | |||
| C8 | 1.950 – 3.000 | 1.950 – 3.000 | |||
| T4 | 700 – 1.400 | 700 – 1.400 | |||
| Landing | C2 – T2 – T3 | 600 – 1.400 | 600 – 1.400 | ||
| C4 | 600 – 3.000 | 600 – 3.000 | |||
| C6 | 1.200 – 3.000 | 1.200 – 3.000 | |||
| C8 | 1.950 – 3.000 | 1.950 – 3.000 | |||
| T4 | 700 – 1.400 | 700 – 1.400 | |||
| EN 81-20/50 Safety rules |
EN 81-21 Existing buildings |
EN 81-28 Remote alarm |
EN 81-71 Vandal resistance lifts Cat. I |
EN 81-72 Firefighters lifts |
EN 81-73 Behaviour of lifts |
|
| Steel Panels | Glass Panels | |||||||||
Sheet metal![]() |
Double skin![]() |
Vision![]() |
Fritted vision![]() |
Wien type vision![]() |
Bevel big vision![]() |
Flush big vision![]() |
Full glass in Skirting![]() |
|||
| Car | OK | OK | OK | OK | OK | OK | OK | OK | ||
| Landing | NO F.R F.R.E30 F.R.E60 F.R.E120 F.R.EI30 F.R.EI60 F.R.EI120 F.R.EW60 |
NO F.R F.R E120 |
NO F.R | NO F.R | NO F.R | NO F.R | NO F.R | NO F.R | ||
| Type | Synchronous PM. Synchronous brushless permanent magnets motor PM 20 230 V AC | |||
| Efficiency | 80% | |||
| Consumptions | Standby 4 W / Average per cycle 20 W | |||
| Transmission | Gearless | T2 – T3 – T4 – C2 – C4 (PL 600 – 1.400) | HTD 5M Belt | |
| C4 (PL 1.450 – 3.000) – C6 – C8 | RPP 5M -5 HS | |||
| Type | VF5+, VF7+ Relay | |||
| Adjustable parameters via | PC / Console | |||
| Working signals available | From 12 V to 230 V AC/DC | |||
| Opening speed | Up to 1 m/s. Manually adjustable and auto-adjustable directly with the panel weight | |||
| Closing speed | Up to 0,6 m/s. Manually adjustable and auto-adjustable directly with the panel weight | |||
| Re-opening | Integrated with auto-adjustable cycles | |||