Premium High Rise (HR) landing and car door solutions are specifically designed to meet the demanding requirements of tall buildings and skyscrapers. These doors seamlessly combine sophisticated design with exceptional functionality and durability, supporting lift speeds of up to 8 m/s.
Note: Premium PM HR cabin doors are designed to support lift speeds of up to 7 m/s, while Premium HR landing doors are suitable for speeds of up to 8 m/s.
| Door cycles per year: | Up to 2.500.000 | ||
| Traffic peak of the door: | Up to 360 cycles per hour | ||
| Traffic lift speed: | Up to 6 m/s |
| Opening | Clear opening – PL (mm) | Clear height – HL (mm) | |||
| Steel Panels | Glass Panels | Steel Panels | Glass Panels | ||
| Car & Landing | C2 | 700 – 2.400 | 2.000 – 2.300 | 2.000 – 2.100 | |
| C4 | 900 – 2.800 | 1.200 – 1.700 | |||
| C6 | 1.600 – 3.000 | – | |||
| T1 | 600 – 1.200 | 2.000 – 2.400 | – | ||
| T2 | 700 – 1.600 | 2.000 – 2.300 | 2.000 – 2.100 | ||
| T3 | 700 – 2.000 | 1.000 – 1.700 | |||
| EN 81-20/50 Safety rules |
EN 81-21 Existing buildings |
EN 81-71 Vandal resistance lifts |
EN 81-72 Firefighters lifts |
|
| Steel Panels | Glass Panels | |||||||||
Sheet metal![]() |
Double skin![]() |
Vision![]() |
Bevel big vision![]() |
Flush big vision![]() |
Full glass in Skirting![]() |
Full glass in mooring![]() |
||||
| Car | OK | OK | OK | OK | KO | OK | OK | |||
| Landing | F.R.E120 F.R.EI30 F.R.EI60 F.R.EI120 F.R.EW30 F.R.EW60 |
F.R E120 F.R.EW60 |
F.R E120 | F.R.E120 F.R.EI30 |
No F.R. F.R.E120 F.R.E60 F.R.EI30 |
No F.R. | No F.R. | |||
| Type | Synchronous PM | |||
| Efficiency | 80% | |||
| Consumptions | Standby 4 W / Average per cycle 20 W | |||
| Transmission | All Range gearless | HTD 5M Belt | ||
| Type | VF5+ Relay, VF6 CAN | VF7+ Relay, VF7+ CAN, DC+ CAN | ||
| Adjustable parameters via | PC / Console | PC / Display | ||
| Working signals available | From 12 V to 240 V AC/DC or with BUS CAN | |||
| Opening speed | Up to 1 m/s (Adjustable) | |||
| Closing speed | Up to 0,6 m/s. Auto-adjusted directly with the panel weight | |||
| Re-opening | Integrated with auto-adjustable cycles | |||